Henan Sinofiltec Technology Co.,Ltd
Auto Self-washing Water Filters,Auto Vertical Backwashing Filter,Automatic Back-cleaning Filters
Model No.: FST-ASF-06/08/10/12/14/16 (DN/Inch)
Brand: SINOFILTEC
Type: Ozone Water Purifier
Motive Force: Electric power
Style: Vertical
Performance: Efficient Filtration
Packaging: Plywood box or standard export packing
Productivity: 500 PCS/YEAR
Transportation: Ocean,Land,Air
Place of Origin: XINXIANG, CHINA
Supply Ability: 500 PCS/YEAR
Certificate: ISO9001
HS Code: 8421999000
Port: SHANG HAI,QINGDAO,ZHENGZHOU
Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
Automatic Sucking Self-Cleaning Water Filter (FST-ASF-06/08/10/12/14/16):
Production describle:
1.Principle of Operation:
When the asf backwash self-cleaning filter works, the turbid liquid enters the lower chamber of the filter through the inlet and the inner cavity of the filter core through the diaphragm hole. The impurity larger than the gap of the filter core is intercepted, the net liquid passes through the gap to the upper cavity, and finally it is sent out from the outlet. The machine is vertical, vertical installed on the pipe, the water to be passed from the inlet into the filter.
The filter element of electric suction filter adopts high strength sintered screen and automatically cleans filter element by pressure difference control and timing control. When the impurity accumulates on the surface of the filter core, the pressure difference between inlet and outlet increases to a set value, or the timer reaches the preset time, the electric control box sends out a signal to drive the backwashing mechanism. When the inlet of the backwash sucker is directly opposite to the inlet of the filter, the drain valve is opened, and the system releases the pressure and drains, and a negative pressure area with a relative pressure lower than the water pressure outside the filter element appears inside the sucker and the filter core. The net circulating water is forced to flow into the inner side of the filter core from the outside of the filter core, and the impurity particles adsorbed on the inner wall of the filter core flow with water into the sucker and discharge from the drain valve.
During the whole self-cleaning process, the filtered water continues to flow out from the outlet. The electronic control system controls the self-cleaning process of the electric automatic cleaning screen filter by the differential pressure meter. If the pressure difference does not change after a self-cleaning cycle, the second self-cleaning will take place in 30 seconds. Electronic control system installed manual cleaning press twist to facilitate manual operation.
Screen: Stainless Steel, Other special material.
Shaft Components: Stainless Steel, Nylon. PVC.
Drain Valve: Cast lron, Brass, Stainless Steel.
Product Advantages:
①Short self-cleaning time and small pressure loss.
②Through the finite element analysis, the brush shaft, which is the critical component, obtains the better structure, and strength.
③Inteligent control(PLC), high degree of automation.
④ Suit for various of raw water qualities and requirements.
⑤ Less vulnerable parts, no consumables, less running costs.
⑥Self-cleaning with continuous flow.
⑦Long life service time.
Product Technical Parameter:
Model | DN | Flow | Filtration Area | Motor Power | Weight | |
|
|
|
|
|
| |
| inch | mm | m³/h | cm2 | kw | Kg |
ASF-06 | 6 | 150 | 150 | 2890 | 0.18 | 175 |
ASF-08 | 8 | 200 | 300 | 4820 | 0.18 | 200 |
ASF-10 | 10 | 250 | 400 | 6830 | 0.18 | 290 |
ASF-12 | 12 | 300 | 600 | 9240 | 0.75 | 330 |
ASF-14 | 14 | 350 | 900 | 10500 | 0.75 | 440 |
ASF-16 | 16 | 400 | 1100 | 10500 | 0.75 | 460 |
1.Single flow: 300-900 cubic meters per hour, can connect more flow through multiple small working pressure: 0.2MPa.
2.Maximum working pressure: 1.6MPa, 2.5MPa, 4.0MPa.
3.High working temperature: 70 °C
4.Filtration accuracy: 25-3500 microns.
5.Control method: differential pressure, time and manual.
6.Cleaning time: 90 seconds.
7.Cleaning mechanism speed: 14 rpm cleaning pressure loss: 0.01 MPa round nozzle, suction scanner for spiral motion.
8.Control voltage: 220V AC rated working voltage: three-phase, 220V, 380V, 50HZ.
ASF strainer installation schematic:
Model | Dimensions | ||||||
D | H | H* | H1 | H2 | L1 | L2 | |
mm | |||||||
ASF-06 | 325 | 1900 | 2000 | 500 | 895 | 400 | 350 |
ASF-08 | 325 | 2200 | 2500 | 700 | 1195 | 400 | 350 |
ASF-10 | 426 | 2305 | 2700 | 700 | 1305 | 400 | 420 |
ASF-12 | 426 | 2635 | 3400 | 1000 | 1625 | 540 | 420 |
ASF-14 | 530 | 2640 | 3400 | 1000 | 1630 | 540 | 480 |
ASF-16 | 530 | 2640 | 3400 | 950 | 1630 | 540 | 500 |
Product Categories : Water Filters > Automatic Self-cleaning Filters